M C Q s D r i v e

Chemical Engineering Mcqs 9594 MCQs [All-Courses]

thumb

Chemical Engineering MCQs designed for job test and interview preparation, particularly for fresh graduates, students, and candidates appearing in competitive exams. These multiple-choice questions cover important topics such as the fundamentals of chemical engineering, chemical processes, chemical reactions, process control, and instrumentation, along with other key concepts in the field.

For two non-interacting first order systems connected in series, the overall transfer function is the ______________ of the individual transfer functions?
A Product
B Ratio
C Sum
D Difference
Correct Answer: Product
Which of the following thermocouples is capable of measuring a temperature of -50°C ?
A Platinum-platinum + rhodium
B Chromel-Alumel
C Iron-constantan
D Copper-constantan
Correct Answer: Platinum-platinum + rhodium
Reference points i.e., ice point and steam point in Reaumer temperature scale are respectively_________________?
A – 273° & 80°
B 0° & 80°
C 32° & 460°
D 32° & 80°
Correct Answer: 0° & 80°
Non-metallic diaphragm used as pressure sensor in instruments is generally made of__________________?
A Teflon
B Synthetic rubber
C Bakelite
D Thick paper
Correct Answer: Synthetic rubber
In second order underdamped system ?
A Decay ratio = overshoot
B Decay ratio = (overshoot)2
C Overshoot increases for increasing damping co-efficient
D Large damping co-efficient means smaller damping
Correct Answer: Decay ratio = (overshoot)2
Bimetal strips are not used in________________?
A Bimetallic thermometers
B Thermocouples
C Thermostats
D Relays for opening & closing of electrical circuits
Correct Answer: Thermocouples
A manometer measures the _____________ pressure?
A Atmospheric
B Absolute
C Gauge
D None of these
Correct Answer: Gauge
Compositional analysis of flue gas coming out of a furnace in respect of O2 and CO2% can be continuously done by a/an___________________?
A Orsat apparatus
B Thermal conductivity cell
C Zirconia probe
D Chromatograph
Correct Answer: Thermal conductivity cell
Mercury thermometer is commonly used for low temperature measurement. The freezing point and boiling point of mercury are respectively _____________ °C?
A – 39 and 350
B – 51 and 439
C – 79 and 395
D – 10 and 425
Correct Answer: – 39 and 350
A stable system is the one___________________?
A For which the output response is bounded for all bounded input
B Which exhibits an unbounded response to a bounded input
C Which satisfies the conditions for a servo problem
D None of these
Correct Answer: For which the output response is bounded for all bounded input